Client: Saudi Electricity Company (SEC)
Scope: Thirdparty performance testing for PP14 combinedcycle plant, including blockwise and plantwise PMT and NDCT to verify output, heat rate, and equipment efficiency.
Approach: Review instrumentation and calibration, analyze operating data, develop correction curves, prepare ASMEPTC46–compliant test plans, supervise onsite testing, and perform data assessment and reporting..pdf)
Deliverables: PMT/NDCT test plans, calibrated instrumentation list, full performance test reports, correction factors, HRSG/ACC efficiency calculations, and digital + hardcopy documentation..pdf)
Client Value: Verified plant performance, accurate net dependable capacity, identification of performance deficiencies, improved operational insight, and closure of documentation gaps for PP14..pdf)